Symbologies#
All Symbologies#
Disable#
Enable#
1D Symbologies#
Disable#
Enable#
2D Symbologies#
Disable#
Enable#
1D Reverse Symbologies#
Note
Regular barcode: Dark image on a bright background.
Inverse barcode: Bright image on a dark background.
* Only Supports Regular Barcode#
Only Supports Inverse Barcode#
All Supported#
Block Barcodes With URLs#
Block scanning of URL QR codes starting with http://, https://
Disable#
* Disable#
Enable#
Enable#
UPC-A#
Enable/Disable#
Disable#
* Enable#
Transmit Preamble Character#
Preamble characters (country code and system characters) can be transmitted as part of the UPC-A symbology. Select one of the following options to set and transmit a UPC-A preamble to the host: Transmit system characters only, Transmit system characters and country code (“0” for the United States), or Transmit no preamble.
No System Character#
* System Character#
System Character & Country Code#
Transmit Check Character#
Disable#
* Enable#
UPC-E#
Enable/Disable#
Disable#
* Enable#
Transmit Preamble Character#
Preamble characters (country code and system characters) can be transmitted as part of the UPC-A symbology. Select one of the following options to set and transmit a UPC-A preamble to the host: Transmit system characters only, Transmit system characters and country code (“0” for the United States), or Transmit no preamble.
No System Character#
* System Character#
System Character & Country Code#
Transmit Check Character#
Disable#
* Enable#
Convert UPC-E to UPC-A#
* Disable#
Enable#
When Enable is selected,Converts UPC-E decoded data to UPC-A format. After conversion, the data follows the UPC-A format and is affected by UPC-A programming selections (e.g., preamble, check digit).
EAN-8#
Enable/Disable#
Disable#
* Enable#
EAN-8 Extension#
When Enable is selected, the scanner adds five leading zeros to the decoded EAN-8 barcode to extend to 13 digits.
* Disable#
Enable#
Transmit Check Character#
Disable#
* Enable#
EAN-13#
Enable/Disable#
Disable#
* Enable#
Transmit Check Character#
Disable#
* Enable#
Convert EAN13 to ISBN#
* Disable#
Enable#
Convert EAN13 to ISSN#
* Disable#
Enable#
UPC/EAN/JAN Add-On Code#
* Disable#
Enable#
Adaptive#
Note
Disable:When the scanner scans a barcode with an additional code, it decodes the barcode and ignores the additional code. The scanner can also decode barcodes without the additional code.Enable:Scanner only decodes mixed barcodes with additional codes.Adaptive:Scanner decodes a mix of barcodes with and without add-on codes.
Code 128#
Enable/Disable#
Disable#
* Enable#
GS1-128#
Enable/Disable#
Disable#
* Enable#
ISBT 128#
Enable/Disable#
Disable#
* Enable#
128 Barcode Length Limit Setting#
Minimum Length Limit(0~50 Digits)#
Maximum Length Limit(0~50 Digits)#
Code 39#
Enable/Disable#
Disable#
* Enable#
Transmit Check Character#
* Disable#
Enable And Not Transmit#
Enable And Transmit#
Code 39 Full ASCII#
* Disable#
Enable#
Transmit Start And End Characters#
* Disable#
Enable#
Length Limit Setting#
Minimum Length Limit(0~50 Digits)#
Maximum Length Limit(0~50 Digits)#
Code 32#
Convert Code 39 To Code 32 (Italian Pharmaceutical Code)#
Code 32 is a variation of Code 39 used by the Italian pharmaceutical industry. Scan the appropriate bar code below to enable or disable the conversion of Code 39 to Code 32.
* Disable#
Enable#
Code 32 Prefix#
Enabling this parameter adds the prefix character “A” to all Code 32 codes. Before enabling this parameter, you must convert Code 39 to Code 32 (Italian Pharmaceutical Code)
* Disable#
Enable#
Code 93#
Enable/Disable#
Disable#
* Enable#
Length Limit Setting#
Minimum Length Limit(0~50 Digits)#
Maximum Length Limit(0~50 Digits)#
Code 11#
Enable/Disable#
* Disable#
Enable#
Transmit Check Character#
* Disable#
Enable#
Check Digit Verification#
This feature allows the scanner to check the integrity of all Code 11 symbologies to verify that the data conforms to a specified check digit algorithm. This selects the check digit mechanism for the decoded Code 11 barcode. Options include checking one check digit, checking two check digits, or disabling the feature.
* Disable#
One Check Digit#
Two Check Digits#
Length Limit Setting#
Minimum Length Limit(0~50 Digits)#
Maximum Length Limit(0~50 Digits)#
Interleaved 2 of 5/ITF#
Enable/Disable#
Disable#
* Enable#
Transmit Check Character#
* Disable#
Enable And Not Transmit#
Enable And Transmit#
Length Selection#
Any length (4-24 Digits)#
6-Digit Length#
8-Digit Length#
10-Digit Length#
12-Digit Length#
14-Digit Length#
16-Digit Length#
18-Digit Length#
20-Digit Length#
22-Digit Length#
24-Digit Length#
Length Limit Setting#
Minimum Length Limit(0~50 Digits)#
Maximum Length Limit(0~50 Digits)#
Industrial 2 of 5#
Enable/Disable#
* Disable#
Enable#
Length Limit Setting#
Minimum Length Limit(0~50 Digits)#
Maximum Length Limit(0~50 Digits)#
Matrix 2 of 5#
Enable/Disable#
* Disable#
Enable#
Length Limit Setting#
Minimum Length Limit(0~50 Digits)#
Maximum Length Limit(0~50 Digits)#
Codabar#
Enable/Disable#
* Disable#
Enable#
Transmit Start/End Character#
* Disable#
Enable#
Length Limit Setting#
Minimum Length Limit(0~50 Digits)#
Maximum Length Limit(0~50 Digits)#
MSI/MSI Plessey#
Enable/Disable#
* Disable#
Enable#
Check Digit Verification#
* One Check Digit#
Two Check Digits#
Transmit Check Character#
* Disable#
Enable#
Check Digit Algorithm#
When the Two MSI Check Digits option is selected, additional verification is required to ensure integrity. Select one of the following algorithms:
MOD 10/MOD 11#
* MOD 10/MOD 10#
Length Limit Setting#
Minimum Length Limit(0~50 Digits)#
Maximum Length Limit(0~50 Digits)#
GS1 DataBar/RSS#
Enable/Disable#
* Disable#
Enable#
GS1 DataBar Limited#
* Disable#
Enable#
GS1 DataBar Expanded#
* Disable#
Enable#
PDF417#
Enable/Disable#
Disable#
* Enable#
Length Limit Setting#
Minimum Length Limit(1~2750)#
Maximum Length Limit(1~2750)#
Micro PDF417#
Enable/Disable#
Disable#
* Enable#
Length Limit Setting#
Minimum Length Limit(1~366)#
Maximum Length Limit(1~366)#
QR Code#
Enable/Disable#
Disable#
* Enable#
Length Limit Setting#
Minimum Length Limit(1~7089)#
Maximum Length Limit(1~7089)#
Micro QR#
Enable/Disable#
Disable#
* Enable#
Length Limit Setting#
Minimum Length Limit(1~35)#
Maximum Length Limit(1~35)#
Data Matrix(DM)#
Enable/Disable#
Disable#
* Enable#
Length Limit Setting#
Minimum Length Limit(1~3116)#
Maximum Length Limit(1~3116)#
Aztec Code#
Enable/Disable#
* Disable#
Enable#
Length Limit Setting#
Minimum Length Limit(1~3832)#
Maximum Length Limit(1~3832)#
Febraban#
Warning
Before enabling the Frbraban function, please disable the AIM ID function first.
Enable/Disable (ITF25)#
* Disable#
Enable#
Enable/Disable (Code128)#
* Disable#
Enable#
Code Verification#
* Disable#
Enable#
Digital Barcode#
0#
1#
2#
3#
4#
5#
6#
7#
8#
9#
A#
B#
C#
D#
E#
F#
Cancel Current Settings#
Cancel String Of Data Read Previously#
Cancel Previous Read Data#
Save#